Brand Name : OEM

Model Number : 60*60mm

Certification : CE/ROHS/TUV

Place of Origin : ZHEJIANG,CHINA

MOQ : 500pcs

Payment Terms : L/C, T/T, Western Union

Supply Ability : 3000 Piece/Pieces per Week Panel Meter

Delivery Time : Shipped in 15 days After Payment

Packaging Details : 1PCS INNER PACKAGE BOX;200PCS Standing Export Carton.

Type : Panel Ammeter

Display Type : Analog Only

Measuring Range : 0-30A AC

Accuracy Class : 2.5

Supply Voltage : 0-600V AC

Dimensions : 60*60mm

Material : ABS Plastic

Pointer color : Red Standard

Usage : Amp Measurement

Operating Temperature : 10℃ ~+55℃

Contact Now

60*60mm Series Analog Panel Meter

Panel Meter Description:

Uses and applications:

This series of meters is a direct imitation of power measurement display instruments, measuring DC current and voltage, AC current and voltage, frequency, power factor, phase sequence power, synchronization instructions and other non-power measurements. It has been widely used in a variety of AC and DC transmission and distribution systems, power control panels and other electrical devices, in the industries of maritime shipping, rail transport, chemical flameproof, low voltage equipment, construction equipment, generators, machinery equipment, etc. Being able to make electrical measurement and non-power measurement, it is a high-end instrument applied in general environmental conditions.

Standards and certifications:

The pointer meter is produced on the standard of GB/T7676-1998 and the digital meter is on the standard of GB/T22264- 2008. Its safety performance is on the standard of GB4793 and IEC61010. The dial scale line and the pointer is designed to meet the German standards of DIN43790 and DIN43802. The shape and hole size of the meter is on the standards of GB/T1242 and IEC61554. All the products of MEIHENG meters Company have gone through the national CE certification, and have got ISO: 9001 certification.

The outer casing of the panel meter:

The base of the series of meters is made of TBT flame-retardant plastic, and its Vicat temperature is 130℃. The outer shell is made of ABS flame-retardant plastic, and its vicat temperature is 85℃.

Accuracy Level:

The pointer meter: AC and DC voltmeter and ammeter to the level of 1.5 or 2.5 power meter to the level of 2.5, frequency meter Accuracy level to the level of 2.5, and power factor meter to the level of 2. 5.

The surface of the dial:

The surface of the dial uses aluminum alloy, white paint, black ink printing or laser printing. The dial can be customized according to the customer sample dials (overprint colors can be customized). The luminous dial uses the PC panel.

Zero regulator:

Except the reading meters without mechanical zero, all other meters have pre-positive zero regulator, used to adjust the meter machinery zero.

Benefits of the product (the dial can be replaced):

For the pointer meter, you can open the sealing, insert or outer the dial. As for the AC ammeter, as long as the secondary current of the transformer is the same, you can replace the dial with the accuracy unchanged. As for the DC ammeter, as long as the shunt output signal or the meter input signal is the same, you can replace the dial even if the meter is of different specifications, with the accuracy unchanged.

Technical Specification:

Product Name Code Accuracy Level Normal Specification Remark
AC Ammeter A 1.5 0.5-50A Can be directly connected
AC Ammeter A 1.5 10/5A-800/5A Secondary current passed by Current transformer
AC Ammeter KA 1.5 1KA-10KA Secondary current passed by Current transformer
AC Voltmeter V 1.5 10V-600V Can be directly connected
AC Voltmeter KV 1.5 1KV-35KV 100V Secondary Voltage passed by voltage transformer
DC Ammeter uA,mA 2.5 50uA-500uA;1mA-500mA Can be directly connected
DC Ammeter A 1.5 1A-15A Can be directly connected
DC Ammeter A 1.5 15A-750A Outer attached shunt
75mV,60mV,50mV
DC Ammeter A 1.5 1KA-3KA Outer attached shunt
75mV,60mV,50mV
DC Voltmeter V 1.5 3V-600V Can be directly connected
DC Voltmeter KV 1.5 1KV-3KV Outer attached Resistance value.
Hz Meter Hz 2.5 45-55Hz,55-65Hz 36V,100V,127V,220V,380V
Power Meter KW.VAR 2.5 100V 380V 380V-380KV 100V Secondary Voltage passed by voltage;
Secondary current passed by Current transformer 5-10KA/5A
COS Meter COS 2.5 COS=0.5-1-0.5

100V/5A,220V/5A,380V/5A


Outline and Mounting Dimensions:
Construction Equipment Analog Panel Amp Meter Analog Ammeter Panel Mount
Construction Equipment Analog Panel Amp Meter Analog Ammeter Panel Mount

Model Specification:

The Installation:

Unless specified, the meter is usually installed in a vertical position. Other installation positions such as horizontal and inclined position can The installation be installed according to the customer requirements. The corresponding level of accuracy is only valid to the regulated installation position. The meter has two kinds of instruction angles: right angle 90 wide angle 250.

Anti-vibration and anti-shock:

Anti-vibration: complies with the standard of IEC60068-2-6; frequency sweep range: 10-55-10Hz; displacement amplitude:±0.15mm,±0.3mm; Frequency sweep cycles: 5 times; sweep rate 10ct/min, maximum acceleration: 147m/s2(15g), 490m/s2 (50g); RMS acceleration: 6. 06g; vibration time:15 min. Anti Machinery shock: complies with the standard of lEC60068-2-27.

Overload ammeter:

The conventional overload multiple times should be once or twice, and it can be customized to once, twice, 3 times and so on according to the user requirements. Its function is to indicate the approximate transient overload current value, such as the start-up current when the motor stars, and so on.

Extrinsic current shunt:

The voltage specifications of the extrinsic current shunt of DC ammeters are 150mV, 100mV,75mV, 60mV and 50mV, which can be customized. The resistance of the conducting wire connecting the meter and the current shunt should within the range of 15-25mto ensure the accuracy of the meter.

Further information:

1. Plastics materials: all raw materials are brand-new and second-hand materials are forbidden. Furthermore some of them are supplied by super branding companies like DSM, Mitsubishi.

2. There is just one level of quality as A in MEIHENG and we are aim to provide the excellent articles to our clients and help them gain more market shares.

3. ODM: we are providing ODM services to the super companies (more than 15) who are top-10 electrical industrial companies in their country. Just show us your ideas and we will present a solution.

FAQ

A. How's the delivery time?
Depend on your quantity, usually within 20days after receiving deposit

B. Would you accept OEM/ODM service?

Glad to say that there is planning department, technical department and mould tooling center in

our factory. For the OEM & ODM, it is ok for us if your brand, market shares are great.


Product Tags:

panel mount analog amp meter

      

analog ammeter panel mount

      
Quality Construction Equipment Analog Panel Amp Meter Analog Ammeter Panel Mount for sale

Construction Equipment Analog Panel Amp Meter Analog Ammeter Panel Mount Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: WENZHOU MEIHENG ELECTRIC CO.,LTD
*Subject:
*Message:
Characters Remaining: (0/3000)